L Firmware 1.37 - 09/2006 55
9400 HighLine | Parameter setting & configuration
Drive interface
Controller commands
0x9B0B Rotor position adjustment cannot be executed since the current
controller test mode is active.
51
0x9B12 Motor identification cannot be started since the current controller
test mode is active.
71, 72
0x9B13 Motor identification cannot be started since the V/f test mode is
active.
71, 72
0x9B14 Motor identification cannot be started since the rotor position
adjustment is active.
71, 72
0x9B15 Motor identification has been aborted. 71, 72
0x9B16 Motor identification has been aborted by fault. 71, 72
0xA001 Access to file has been denied since the file is already accessed from
another position
11,
201, 202, 203, 204,
301, 302, 303, 304
0xA005 I/O fault when accessing the file system. 11,
201, 202, 203, 204,
301, 302, 303, 304
0xA00C RAM memory is full. 11,
201, 202, 203, 204,
301, 302, 303, 304
0xA00D Access authorisation denied. 11,
201, 202, 203, 204,
301, 302, 303, 304
0xA01C No free memory on the memory module. 11,
201, 202, 203, 204,
301, 302, 303, 304
Bit 0 ... 15 Status Concerns device