L Firmware 1.37 - 09/2006 155
9400 HighLine | Parameter setting & configuration
Basic drive functions
Quick stop | System block "LS_quick stop"
9.3.3 System block "LS_quick stop"
The LS_quick stop system block in the function block editor maps the basic function "Quick
stop".
Inputs
Outputs
Identifier
DIS code | data type
Information/possible settings
QSP_bActivate1
C02619/1 | BOOL
QSP_bActivate2
C02619/2 | BOOL
QSP_bActivate3
C02619/3 | BOOL
Activate quick stop
The three inputs are linked via a logic OR gate.
TRUE If one of the three inputs is set to TRUE, it is changed to the function
state "Quick stop active" and the drive is braked to standstill within
the deceleration time set for quick stop.
TRUEÌFALSE When all three inputs are reset to FALSE, it is changed to a setpoint-
generating basic function (e.g. "speed follower") via the function
state "Drive is stopped".
Identifier
DIS code | data type
Value/meaning
QSP_bActive
C02619/4 | BOOL
Status output "quick stop is active"
TRUE Quick stop is active.
LS_Quickstop
QSP_bActivate1 QSP_bActive
STOP