Vista de pagina 254
L Firmware 1.37 - 09/2006 255
9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – speed" | Speed follower
11.2.5 Speed follower
[11-8] Basic function "Speed follower" (schematic diagram)
The speed-controlled operation is requested via the digital input DI2. If no other basic
function and error state are active, the speed-controlled operation is enabled.
r The acceleration/deceleration of the drive to the setpoint is controlled via a ramp
generator based on the current setpoint/actual speed.
r If the enable of the speed-controlled operation is reset via the digital input DI2, the
drive is decelerated to standstill via an independent profile generator of the basic
function "Stop". Standard stop
(C 148)
O Tip!
Detailed information on the speed follower can be found in the chapter "basic drive
functions" subchapter "Speed follower
". (C 190)
LS_ManualJog
n
t
è
ç
LS_Brake
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
Gain
Invert setpointSelection
LS_Speed...
M
Speed
setpoint
n
t
LS_Stop
internal
status machine
DI2
DI6
DI7
DI8
DI1
DI3DI4
OUT
IN
Ramp generator
%1
%2
%15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint Basic drive functions
AIN1
M
v
è
ç
Vista de pagina 254