TA "Actuator – speed" | Assignment of the I/O terminals
11.2.2.2 Actual value and status signals
The following tables contain the Lenze assignment of the analog and digital outputs for
the technology application "actuator – speed".
r The default signal configuration if required can be easily changed by parameterising
the multiplexer parameters assigned.
Analog outputs
Digital outputs
State bus
Terminal X3 Signal (Lenze setting) Signal configuration
AO1 Motor speed
• Scaling: ±10 V ≡ motor reference speed (C00011
)
C03110/1
AO2 Motor torque (setpoint)
• Scaling: ±10 V ≡ Motor reference torque (C00057/2
)
C03110/2
I/O terminalsAnalog outputs (C 120)
Terminal X4 Signal (Lenze setting) Signal configuration
DO1 Status "Drive ready"
• This operating state is active if the controller is enabled by setting
the digital input RFR to HIGH level and no error has occurred.
C03100/1
DO2 Status "Speed follower enabled"
• The speed follower has been enabled via the digital input DI2.
C03100/2
DO3 Status "Speed follower in limitation"
• The enabled speed follower is in the limitation for more than
100 ms.
• The setpoint is limited to the upper or lower speed limit value
(C00909/1
or C00909/2) .
C03100/3
DO4 Status "Error active acknowledgement is required"
• Monitoring with the error response "Error" or "Quick stop by
trouble" has been activated, and the controller is in the device
state "Error active" or "Quick stop by trouble active".
C03100/4
I/O terminalsDigital outputs (C 125)
Terminal X2 Signal (Lenze setting) Signal configuration
SB Status "Speed follower in limitation"
• The enabled speed follower is in the limitation for more than
100 ms.
• The setpoint is limited to the upper or lower speed limit value
(C00909/1
or C00909/2) .
• The state bus is put in the "error" status.
C03100/5
I/O terminalsMonitoring function "State bus" (C 127)