9400 HighLine | Parameter setting & configuration
Parameter reference
Structure of the parameter descriptions
542 Firmware 1.37 - 09/2006 L
16.1.4 Parameter attributes
Type of access
r The first four attributes provide information about the parameter access:
Additional features
r The following attributes refer to the parameter set transfer to the controller:
Scaling factor
r The "scaling factor" is important for parameter access via bus systems. It is only
indicated for parameters using a data format with decimal positions:
Attribute Meaning
; Read access Read access to parameter possible.
; Write access Write access to parameter possible.
• Please also observe the following attributes:
; CINH Parameter value can only be changed when the controller is
inhibited.
; PLC STOP Change of the parameter value is only possible when the application
is stopped.
Attribute Meaning
; No transfer Parameter is not transferred to controller when the command Download parameter set is
executed.
; COM "PC communication parameter"
•In the Download parameter set or Download application dialog box, you can select that
PC communication parameters are not to be transferred to the controller.
; MOT "Motor data parameter"
•In the Download parameter set or Download application dialog box, you can select that
motor data parameters are not to be transferred to the controller.
Read value (via bus system) Scaling factor indicated value (Engineer)⋅=