L Firmware 1.37 - 09/2006 547
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00005
C00005
C00006
C00007
C00011
C00018
C00019
Parameter | Name:
C00005 | Application selection
Data type: INTEGER_32
Index: 24570
d
= 5FFA
h
Application selection
Use the controller command C00002
="5" to activate the selected application.
Setting range
(min. value | unit | max. value) Lenze setting
-1 16 0
; Read access ; Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00006 | Motor control selection
Data type: UNSIGNED_32
Index: 24569
d
= 5FF9
h
Selection list (Lenze setting printed in bold) Information
1 Servo control with SM For synchronous motors with speed sensor
2 Servo controller with ASM For asynchronous motors with speed sensor
; Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00007 | Active application
Data type: UNSIGNED_32
Index: 24568
d
= 5FF8
h
Display range (min. value | unit | max. value)
0 4294967295
; Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00011 | Motor reference speed
Data type: UNSIGNED_32
Index: 24564
d
= 5FF4
h
For parameter setting via interface: In case of bigger changes, only change the setting in one step when the
controller is inhibited!
Setting range
(min. value | unit | max. value) Lenze setting
50 rpm 50000 3000 rpm
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00018 | Chopper frequency
Data type: UNSIGNED_32
Index: 24557
d
= 5FED
h
Selection list (Lenze setting printed in bold) Information
21 kHz fixed Note:
The maximum output frequency of the controller is
limited to 1/8 of the switching frequency selected here!
32 kHz fixed
44 kHz fixed
58 kHz fixed
82 kHz variable
94 kHz variable
10 8 kHz variable
11 16 kHz variable
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00019 | Zero speed detection threshold
Data type: UNSIGNED_32
Index: 24556
d
= 5FEC
h
Setting range (min. value | unit | max. value) Lenze setting
0 rpm 450 5 rpm
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Vista de pagina 546