9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00610
594 Firmware 1.37 - 09/2006 L
C00610
C00611
C00612
Parameter | Name:
C00610 | Resp. to heatsink fan failure
Data type: UNSIGNED_32
Index: 23965
d
= 5D9D
h
Response if fan speed of heatsink fan is too low.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00611 | Resp. to integral fan failure
Data type: UNSIGNED_32
Index: 23964
d
= 5D9C
h
Response if fan speed of interior fan is too low.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00612 | Resp. to CAN node guarding error
Data type: UNSIGNED_8
Index: 23963
d
= 5D9B
h
Response of master, if the corresponding node guarding response is not received.
Selection list
0 No response
1 Error
2Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
Subcodes Lenze setting Information
C00612/1 0: No response Response to non received telegram for monitoring entry
1 ... 32
C00612/...
C00612/32
; Read access ; Write access CINH PLC STOP No transfer COM MOT