Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37 Manual de usuario Pagina 261

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 679
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 260
L Firmware 1.37 - 09/2006 261
9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – speed" | Signal configuration of drive and motor interface
11.2.10 Signal configuration of drive and motor interface
If required, the preset signal configuration of the control and setpoint inputs of the drive
and motor interface can be easily reconfigured per parameter setting of the assigned
multiplexer parameters.
Drive interface
Motor interface
Signal (Lenze setting) Control input Signal configuration
FALSE Set controller inhibit C03130/1
DigIn 5 Reset error 1 C03130/2
Control word 1 bit 07 Reset error 2 C03130/3
FALSE Reset error 3 C03130/4
FALSE Set error C03130/5
Control word 1 bit 00 Switch on drive C03130/6
Signal (Lenze setting) Setpoint input Signal configuration
100 % Upper torque limit value C03141/1
-100 % Lower torque limit value C03141/2
Vista de pagina 260
1 2 ... 256 257 258 259 260 261 262 263 264 265 266 ... 678 679

Comentarios a estos manuales

Sin comentarios