9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
82 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.9.8 Overview of CiA402 homing modes
Short overview
CiA402 homing
method
Evaluated signals/sensors
Encoder zero pulse/
touch probe sensor
Negative
travel range limit switch
Positive
travel range limit switch
Reference switch
-2 Positive direction of rotation at torque limit.
-1 Negative direction of rotation at torque limit.
01 ;;
02 ;;
03 ;;
04 ;;
05 ;;
06 ;;
07 ;;;
08 ;;;
09 ;;;
10 ;;;
11 ;; ;
12 ;; ;
13 ;; ;
14 ;; ;
15 Reserved: Homing is not carried out.
16 Reserved: Homing is not carried out.
17 ;
18 ;
19 ;
20 ;
21 ;
22 ;
23 ;;
24 ;;
25 ;;
26 ;;
27 ;;
28 ;;
29 ;;
30 ;;
31 Reserved: Homing is not carried out.
32 Reserved: Homing is not carried out.
33 ;
34 ;
35 Direct reference setting.