EDS94TA11010xxxx EN 1.2 - 03/2010 L 75
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
3.9.2 Object description
All objects are Lenze-specific.
The 0x609A
object (homing acceleration) is executed as an array according to the
0x6099
object (homing speeds).
All CiA402 homing modes are supported.
The homing modes of the "Homing" basic function are supported 1:1.
Objects described in other chapters:
Objects described in this chapter:
Index Name Data type Object type
Device control
0x6040 Control word UNSIGNED_16 VAR
0x6041 Status word UNSIGNED_16 VAR
Position control function
0x60FB Position control parameter set UNSIGNED_32 RECORD
1: Load home position
INTEGER_32
7: Homing stop mode
UNSIGNED_32
Grayed out = read access only
Index Name Data type Object type
0x607C
Home offset UNSIGNED_32 VAR
0x6098
Homing method INTEGER_8 VAR
0x6099
Homing speeds UNSIGNED_32 VAR
0x609A
Homing acceleration UNSIGNED_32 VAR