EDS94TA11010xxxx EN 1.2 - 03/2010 L 181
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Application error messages
3.20 Application error messages
In order to output application-specific error messages, a L_DevApplErr1 FB instance of the
L_DevApplErr function block is provided in the interconnection.
Up to 8 different application error messages with parameterisable module ID, error ID
and error response can be triggered by the application via the 8 boolean inputs.
The first two inputs are fixed connected to trigger signals of the application, the other
six inputs are free:
Parameterisation: all parameters tab
Error message Error ID Error response
1 DC-bus undervoltage 8001 Quick stop by trouble
2 Maximal value of the telegram failure exceeded 8002 Information
3 Application error (free input) 8003 Error
4 Application error (free input) 8004 Error
5 Application error (free input) 8005 Error
6 Application error (free input) 8006 Error
7 Application error (free input) 8007 Error
8 Application error (free input) 8008 Error
Parameter Lenze setting
C05900 Module ID 999
C05901/1...8 Error ID 1 ... 8 see table above
C05902/1...8 Error response 1 ... 8 see table above
Note!
In general, the "Warning locked" error response should not be set for the
operation of the CiA402 application with a control because the control cannot
distinguish this error response from the "Warning" error response. Therefore, it
cannot be acknowledged.