9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Cyclic synchronous torque mode (IEC 61800-7)
156 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.14 Cyclic synchronous torque mode (IEC 61800-7)
This operating mode provides a fast torque follower with speed limitation. The torque
profile to be processed is defined by the master control.
Subfunctions of the operating mode
Calculation of the torque setpoint
Interpolation between communication cycle and control cycle
Torque control
Limitation of the motor speed
Update of the actual values for position, speed, and torque
Selection of operating mode
The "Cyclic synchronous torque mode" is selected using the value "10" via the 0x6060
object (mode of operation).
3.14.1 Input and output data
Input data
Output data
Index Name Data type Object type
0x6040
Control word UNSIGNED_16 VAR
0x60C2
Interpolation time period UNSIGNED_32 RECORD
0x60B2
Torque offset INTEGER_32 VAR
0x6071
Target torque INTEGER_32 VAR
0x6072
Max. torque UNSIGNED_16 VAR
0x6076 Motor rated torque UNSIGNED_32 VAR
0x60F6
Torque control parameters UNSIGNED_32 RECORD
Index Name Data type Object type
0x6041 Status word UNSIGNED_16 VAR
0x6064 Position actual value INTEGER_32 VAR
0x606C Velocity actual value INTEGER_32 VAR
0x6077 Torque actual value INTEGER_32 VAR
Grayed out = read access only