9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Device control
48 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.7.2.2 Switch on
This command serves to deactivate the switch on inhibit which is active after switch on or
after the reset (acknowledgement) of an error.
It is changed to the device state "Switched on
":
[3-3] Possible state changes through "Switch on" command
Bit pattern for "Switch on" command in 0x6040 (control word):
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reset fault Operating mode-dependent control bits Enable
operation
Quick stop Enable voltage Switch on
0 X X XX111
From all states
Power section inhibited (pulse inhibit)
Power section enabled
1
2
0
Ready to
switch on
Not ready to
switch on
Switched
on
Operation
enabled
Fault reaction
active
Fault
active
Switch on
disabled
Quick stop
active
Power on