EDS94TA11010xxxx EN 1.2 - 03/2010 L 209
9400 Technology applications | CiA402 device profile
Parameter reference
Parameter list | C03583
C03583
C03585
C03590
C03591
C03592
C03593
Parameter | Name:
C03583 | Polarity
Data type: UNSIGNED_8
Index: 20992
d
= 5200
h
CiA402 object 0x607E
Display range (min. value | unit | max. value)
2 2
; Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03585 | Load home position
Data type: INTEGER_32
Index: 20990
d
= 51FE
h
CiA402 object 0x60FB.1
Setting range (min. value | unit | max. value) Lenze setting
-2147483647 2147483647 0
; Read access ; Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03590 | Position demand value unit
Data type: INTEGER_32
Index: 20985
d
= 51F9
h
CiA402 object 0x6062
Display range (min. value | unit | max. value)
1 255
; Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03591 | Position actual value
Data type: INTEGER_32
Index: 20984
d
= 51F8
h
CiA402 object 0x6063
Display range (min. value | unit | max. value)
-2147483647 134217727
; Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03592 | Position actual value unit
Data type: INTEGER_32
Index: 20983
d
= 51F7
h
CiA402 object 0x6064
Display range (min. value | unit | max. value)
-2147483647 134217727
; Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03593 | Following error window
Data type: UNSIGNED_32
Index: 20982
d
= 51F6
h
CiA402 object 0x6065
Setting range (min. value | unit | max. value) Lenze setting
0 4294967295 1000
; Read access ; Write access CINH PLC STOP No transfer Scaling factor: 1