9400 Technology applications | CiA402 device profile
Parameter reference
Parameter list | C03520
202 L EDS94TA11010xxxx EN 1.2 - 03/2010
C03520
C03521
C03522
C03530
C03531
C03532
C03533
Parameter | Name:
C03520 | Error code
Data type: UNSIGNED_32
Index: 21055
d
= 523F
h
CiA402 object 0x603F
Display range (min. value | unit | max. value)
0 4294967295
; Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03521 | Supported drive modes
Data type: UNSIGNED_32
Index: 21054
d
= 523E
h
CiA402 object 0x6502
Display range (min. value | unit | max. value)
0 4294967295
; Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03522 | Drive catalog number
Data type: VISIBLE_STRING
Index: 21053
d
= 523D
h
CiA402 object 0x6503
; Read access ; Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03530 | Control word
Data type: UNSIGNED_16
Index: 21045
d
= 5235
h
CiA402 object 0x6040
Setting range (min. value | unit | max. value) Lenze setting
0 65535 0
; Read access ; Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03531 | Status word
Data type: UNSIGNED_16
Index: 21044
d
= 5234
h
CiA402 object 0x6041
Display range (min. value | unit | max. value)
0 65535
; Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C03532 | Shutdown option code
Data type: INTEGER_16
Index: 21043
d
= 5233
h
CiA402 object 0x605B
Setting range (min. value | unit | max. value) Lenze setting
000
; Read access ; Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01533 | DS402 disable operation option code
Data type: INTEGER_16
Index: 21042
d
= 5232
h
CiA402 object 0x605C
Setting range (min. value | unit | max. value) Lenze setting
000
; Read access ; Write access CINH PLC STOP No transfer Scaling factor: 1