EDS94TA11010xxxx EN 1.2 - 03/2010 L 125
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Position control function
0x60FC - Position demand value*
Index | Name:
0x60FB/7 | Homing stop mode
Data type: UNSIGNED_32
Code: C02641
Drive behaviour after setting the home position
Direct mapping of the Lenze code C02641 (behaviour after detection of home position)
Drive behaviour after setting the home position
Selection list (Lenze setting printed in bold) Information
0 Move absolute on Target position After setting the home position (C02642), the drive
moves to the absolute target position set in C02643.
This selection is the Lenze setting and corresponds to
the behaviour known from the previous versions.
1 Move relative by Target position After setting the home position (C02642), the drive
moves relatively by the target position set in C02643.
2 Stop After setting the home position (C02642), the drive stops
immediately.
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x60FC | Position demand value*
Data type: INTEGER_32
Code: C03600
Interpolated position setpoint for position control in [increments]
Display area
(min. value | unit | max. value)
-2147483648 inc 2147483647
; Read access Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX