
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Common entries
36 L EDS94TA11010xxxx EN 1.2 - 03/2010
0x6403 - Motor catalogue number
0x6404 - Motor manufacturer
0x6405 - http motor catalogue address
0x6406 - Motor calibration date
0x6407 - Motor service period
0x6410 - Motor data
Index | Name:
0x6403 | Motor catalogue number
Data type: VISIBLE_STRING
Code: C03504
Motor catalogue number
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6404 | Motor manufacturer
Data type: VISIBLE_STRING
Code: C31505
Motor manufacturer
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6405 | http motor catalogue address
Data type: VISIBLE_STRING
Code: C03506
http motor catalogue address
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6406 | Motor calibration date
Data type: VISIBLE_STRING
Code: C03507
Motor calibration date
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6407 | Motor service period
Data type: UNSIGNED_32
Code: C03508
Motor service interval in hours
Setting range
(min. value | unit | max. value) Lenze setting
0 4294967295 0
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6410 | Motor data
Data type: UNSIGNED_32
Code: C03509
Motor parameters
Display area
(min. value | unit | max. value)
00
; Read access Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Comentarios a estos manuales