9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Device control
52 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.7.2.6 Disable voltage
This command serves to inhibit the output stages of the controller again.
The pulse inhibit is set (unless they are set already), i.e. the pulses of the controller are
inhibited.
The motor becomes torqueless and coasts if it is not braked.
The switch on inhibit is set again.
It is changed back to the device state "Switch on disabled
".
[3-7] Possible state change through "Disable voltage" command
Bit pattern for "Disable voltage" command in 0x6040 (control word):
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reset fault Operating mode-dependent control bits Enable
operation
Quick stop Enable voltage Switch on
0 X X XXX0X
From all states
Power section inhibited (pulse inhibit)
Power section enabled
1
2
0
Ready to
switch on
Not ready to
switch on
Switched
on
Operation
enabled
Fault reaction
active
Fault
active
Switch on
disabled
Quick stop
active
Power on