EDS94TA11010xxxx EN 1.2 - 03/2010 L 55
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Device control
3.7.3.1 Not ready to switch on
This is the controller status directly after switching on the supply voltage.
In this device state the operating system is initialised.
The monitorings are not active yet.
Communication is not possible yet.
The controller cannot be parameterised yet and no device commands can be executed.
The motor brake, if available, is closed.
The operation is inhibited.
Bit pattern for "Not ready to switch on" device state in 0x6041 (status word):
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Warning Switch on
disabled
Quick stop Voltage
enabled
Fault Operation
enabled
Switched on Ready to switch
on
X0XX0000
Note!
When the device initialisation is completed, the device state is automatically
changed to "Switch on disabled
".
Comentarios a estos manuales