Lenze E94AxHE Technology Application CiA402 Device profi Manual de usuario Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 232
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
EDS94TA11010xxxx EN 1.2 - 03/2010 L 35
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Common entries
0x603F - Error code
The following table contains all possible error numbers and their meaning:
0x6402 - Motor type
Index | Name:
0x603F | Error code
Data type: UNSIGNED_32
Code: C00394
Error number
Display area
(min. value | unit | max. value)
0 4294967295
; Read access Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Error number Meaning
[dez [hex]
0 0x0000 Ok, no error
4096 0x1000 An error has occurred in the controller (system fault, fault, trouble, or
warning).
33024 0x8100 Communication error (warning)
33072 0x8130 Network monitoring function "Node guarding" or "Heartbeat" has tripped.
33296 0x8210 PDO length is lower than expected.
33312 0x8220 PDO length is higher than expected.
34560 0x8700 Monitoring of the sync telegram has tripped.
Index | Name:
0x6402 | Motor type
Data type: UNSIGNED_16
Code: C03503
Motor type
Selection list
(Lenze setting printed in bold)
0 Non-standard motor
1Phase modulated DC motor
2 Frequency controlled DC motor
3 PM synchronous motor
4 FC synchronous motor
5Switched reluctance motor
6 Wound rotor induction motor
7 Squirrel cage induction motor
8 Stepper motor
9 Micro-step stepper motor
10 Sinusoidal PM BL motor
11 Trapezoidal PM BL motor
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Vista de pagina 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 231 232

Comentarios a estos manuales

Sin comentarios