Lenze E94AxHE Technology Application CiA402 Device profi Manual de usuario Pagina 110

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 232
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 109
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
110 L EDS94TA11010xxxx EN 1.2 - 03/2010
CiA402 Homing method 26
Processes:
Case 1: Axis does not activate reference switch on the way to the limit switch:
1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch.
3. Reversing with positive edge of the reference switch and change to profile data set 2.
4. The following negative edge of reference switch sets reference (0x607C
).
5. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Case 2: Axis activates reference switch first on the way to the limit switch:
1. Movement in positive direction with profile data set 1.
2. Positive edge of the reference switch activates profile data set 2.
3. The following negative edge of reference switch sets reference (0x607C
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Case 3: Axis already stands on reference switch:
1. Movement in positive direction with profile data set 2.
2. The following negative edge of reference switch sets reference (0x607C
).
3. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Homing switch
Positive travel range limit switch
2
1
3
0