9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Factor group
70 L EDS94TA11010xxxx EN 1.2 - 03/2010
0x6093 - Position factor
0x6094 - Velocity encoder factor
Index | Name:
0x6093 | Position factor
Data type: UNSIGNED_32
Code: C03568
Factor for position conversions
• Application unit internal unit
• Internal unit application unit
Subindex Name
0x6093/1
Numerator
0x6093/2
Divisor
Index | Name:
0x6093/1 | Numerator
Data type: UNSIGNED_32
Code: C03569
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6093/2 | Divisor
Data type: UNSIGNED_32
Code: C03570
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6094 | Velocity encoder factor
Data type: UNSIGNED_32
Code: C03571
Factor for speed conversions
• Application unit internal unit
• Internal unit application unit
Subindex Name
0x6094/1
Numerator
0x6094/2
Divisor
Index | Name:
0x6094/1 | Numerator
Data type: UNSIGNED_32
Code: C03572
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6094/2 | Divisor
Data type: UNSIGNED_32
Code: C03573
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX