EDS94TA11010xxxx EN 1.2 - 03/2010 L 71
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Factor group
0x6095 - Velocity factor 1
0x6096 - Velocity factor 2
Index | Name:
0x6095 | Velocity factor 1
Data type: UNSIGNED_32
Code: C03574
Factor for speed conversions
• Application unit internal unit
• Internal unit application unit
Subindex Name
0x6095/1
Numerator
0x6095/2
Divisor
Index | Name:
0x6095/1 | Numerator
Data type: UNSIGNED_32
Code: C03575
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6095/2 | Divisor
Data type: UNSIGNED_32
Code: C03576
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6096 | Velocity factor 2
Data type: UNSIGNED_32
Code: C03577
Factor for speed conversions
• Application unit internal unit
• Internal unit application unit
Subindex Name
0x6096/1
Numerator
0x6096/2
Divisor
Index | Name:
0x6096/1 | Numerator
Data type: UNSIGNED_32
Code: C03578
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6096/2 | Divisor
Data type: UNSIGNED_32
Code: C03579
Setting range (min. value | unit | max. value) Lenze setting
111
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX