9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
116 L EDS94TA11010xxxx EN 1.2 - 03/2010
CiA402 Homing method 34
Process:
1. Movement in positive direction with profile data set 1 and activation of the touch
probe detection.
2. The following positive edge of the touch probe sensor sets the reference (0x607C
).
3. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
CiA402 homing method 35
Direct reference setting.
The measuring system is set according to the home position parameterised in the
0x607C
object (home offset).
Touch probe/zero pulse
1
0
1