9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Internal interfaces | function block "L_CiA402DeviceProfile"
178 L EDS94TA11010xxxx EN 1.2 - 03/2010
Outputs
bMI_
bMotorOrientationInverse
BOOL
Interface for the motor interface
Input for the motor mounting position.
Connect this input to the MI_bMotorOrientationInverse output of
the LS_MotorInterface system block.
bMI_
bSpeedBelowThresholdC19
BOOL
Interface for the motor interface
Input for the zero speed recognition.
Connect this input to the bSpeedBelowThresholdC19 output of the
LS_MotorInterface system block.
bPF_bEnabled
BOOL
Interface for the "position follower" basic function
Input for the status signal "position follower basic function active".
Connect this input to the PF_bEnabled output of the LS_Positionfollower system
block.
bSF_bEnabled
BOOL
Interface for the "speed follower" basic function
Input for the status signal "speed follower basic function active".
Connect this input to the SF_bEnabled output of the LS_Speedfollower system
block.
bTF_bEnabled
BOOL
Interface for the "torque follower" basic function
Input for the status signal "torque follower basic function active".
Connect this input to the TF_bEnabled output of the LS_Torquefollower system
block.
dnSMI_dnState
DINT
Interface for the safety module
Input for the status signal.
Connect this input to the SMI_bEnabled output of the LS_SafetyModulinterface
system block.
bSYNC_
bProcessDataExpected
BOOL
Input for the status information "process data expected"
Connect this input to the SYNC_bProcessDataExpected output of
the LS_SyncInput system block.
bSYNC_
bProcessDataInvalid
BOOL
Input for the status information "process data invalid"
Connect this input to the SYNC_bProcessDataInvalid output of the LS_SyncInput
system block.
byDigitalInput
BYTE
Input for the acceptance of the status of the digital inputs
bySafeIOState
BYTE
Input for the acceptance of the I/O status of the safety module
AxisData Input for transfer of the machine parameters of the drive
Connect this input to the output DI_AxisData of the system
block LS_DriveInterface.
Identifier
Data type
Info/meaning
wCiA402StatusWord
WORD
Interface to the master / master control
•Status word (0x6041
). Device statuses
byCiA402
ModeOfOperationDisplay
BYTE
Interface to the master / master control
Active operating mode (0x6061
). Operating mode changeover
dnCiA402ActualPosition_e4
DINT
Interface to the master / master control
Actual position in user units (e4 representation).
dnCiA402ActualPosition_p
DINT
Interface to the master / master control
Actual position in internal units.
dnCiA402
ActualFollowingError_e4
DINT
Interface to the master / master control
Actual following error in user units (e4 representation).
Identifier
Data type
Information/possible settings