Lenze E94AxHE Technology Application CiA402 Device profi Manual de usuario Pagina 65

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 232
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 64
EDS94TA11010xxxx EN 1.2 - 03/2010 L 65
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Factor group
0x607E - Polarity
0x6089 - Position notation index
0x608A - Position dimension index
Index | Name:
0x607E | Polarity
Data type: UNSIGNED_8
Code: C03583
Mounting directions
Subindex Name
0x607E/1
Polarity of motor
0x607E/2
Polarity of load
Index | Name:
0x607E/1 | Polarity of motor
Data type: UNSIGNED_32
Code: C02527
Motor mounting direction
Direct mapping of the Lenze code C02527 (motor mounting direction).
Setting range
(min. value | unit | max. value) Lenze setting
011
; Read access ; Write access ; CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x607E/2 | Polarity of load
Data type: UNSIGNED_32
Code: C02529
Position encoder mounting dir.
Direct mapping of the Lenze code C02529 (position encoder mounting direction).
Setting range
(min. value | unit | max. value) Lenze setting
011
; Read access ; Write access ; CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6089 | Position notation index
Data type: INTEGER_8
Code: C03550
Multiplier for position values (10 exp value, decimal point)
Setting range (min. value | unit | max. value) Lenze setting
000
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x608A | Position dimension index
Data type: UNSIGNED_8
Code: C03551
Unit for position values
Setting range
(min. value | unit | max. value) Lenze setting
000
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Vista de pagina 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 231 232

Comentarios a estos manuales

Sin comentarios