EDS94TA11010xxxx EN 1.2 - 03/2010 L 69
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Factor group
0x6092 - Feed constant
Index | Name:
0x6092 | Feed constant
Data type: UNSIGNED_32
Code: C03565
Feed constant
• The feed constant corresponds to the motion of the machine at one revolution of the gearbox output shaft.
Subindex Name
0x6092/1
Feed
0x6092/2
Shaft revolutions
Index | Name:
0x6092/1 | Feed
Data type: UNSIGNED_32
Code: C02524
Feed
• Direct mapping of the Lenze code C02524 (feed constant).
Setting range
(min. value | unit | max. value) Lenze setting
1 pos unit 2147483647 65536 pos unit
; Read access ; Write access ; CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6092/2 | Shaft revolutions
Data type: UNSIGNED_32
Code: C03567
Number of output shaft revolutions
Setting range
(min. value | unit | max. value) Lenze setting
1rev11rev
; Read access ; Write access CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX