Lenze ETC Motion Control Manual de usuario Pagina 370

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 428
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 369
PLC programming
Library
General functions
8
8.8
8.8.1
l
370
EDSTCXN EN 2.0
8.8.1.19 SPSERROR
FUNCTION SPSERROR: BOOL
VAR_INPUT
fehler_di] : DINT; (* error number *)
klasse_dw : DWORD; (* error class *)
formatstring : STRING(80); (* Format string *)
PARAMETER_P : DINT; (* Address of a structure containing the parameters *)
END_VAR
The function places an error message which is displayed on a connected
control terminal. The error number fehler_di also serves as a reference for an
error text. The error texts can be displayed on a connected PC (for both ETC
variants) or on the ETC MMI (only ETCxC).
The error classes klasse_dw are divided as follows:
1: local minor error
2: local major error
3: global minor error
4: global major error
Error classes 3 and 4 cause the program to be cancelled or result in an axis
movement.
Via the error texts references by the error numbers additional information
can also be output. Via the format string additional text or numerical values
can be transferred.
Declaration
Description
Vista de pagina 369
1 2 ... 365 366 367 368 369 370 371 372 373 374 375 ... 427 428

Comentarios a estos manuales

ama 11 Jan 2025 | 19:35:39

rasha