Getting started
Commissioning steps (overview)
2
2.3
l
20
EDSTCXN EN 2.0
2.3 Commissioning steps (overview)
( Stop!
Observe the notes in the chapter "Initital switch−on" of the ETC
Hardware Manual before commissioning the system.
) Note!
Only build in and install the PCI control variant ETCPx in step 6.
Step ETCHC ETCPC Description See
1X− Connect ETCHC via RS232 cable with PC and start ETCHC. ^ 21
2 X − Start terminal program on the PC (if required, configure in
advance) and activate monitor interface of the ETCHC.
^ 21
3 X − If the ETCHC is to be operated in the "with MMI"
operating mode, replace the firmware file on the ETC by
the file "NetBoot.rsc".
^ 25
4 X − Assign the IP address of the ETCHC. ^ 28
5 X X If required, install ETC−MMI and ETC−MMI Gateway. ^ 31
6 − X Install ETCPC in the PC and install the driver. ^ 31
7 X X Start ETC−MMI and ETC−MMI Gateway. ^ 32
8 X X Establish connection between ETC−MMI and ETCxC. ^ 34
9 X X Parameterise drives via machine constants. ^ 36
10 X X Check parameters of the drives. ^ 43
11 X X Test drives in inching mode. ^ 44
12 X X Create CNC program in the ETC−MMI. ^ 47
13 X X Load CNC program into ETCxC, start and test CNC
program.
^ 49
14 X X If required, install CoDeSys. ^ 51
15 X X Start and configure CoDeSys. ^ 51
16 X X Create PLC program. ^ 60
17 X X Load PLC program into ETCxC, start and test PLC program. ^ 68
18 X X Test CNC and PLC program. ^ 72
rasha