CNC programming
Data fields
P field
3
3.5
3.5.1
l
185
EDSTCXN EN 2.0
UnitSyncMeaningIndex
588 Current processing state of channel N for diagnosis
purposes
0: Idle
1: Run
2: Brake termination
3: Termination wait quit
4: Termination
5: Brake interrupt
6: Interrupt
7: Brake block jump
8: Block jump
9: Brake interrupt
10: Interrupt
11: Brake error
12: Error
13: Balancing run
x
589 Current increment, e.g. stitch length during sewing x mm *
590 Current interpreter state
0: No program active
1: Single function active
2: Program active
3: Interrupt program active
x −−−
591 Bit coded state of modal functions
Bit0: 0=route operation (G30), 1=path operation (G31)
Bit1: 0=empty run (M15,M16,M21), 1=profile (M14)
Bit2: 0=event handler disabled (G132), 1=event handler
enabled (G133)
Bit3: 0=override enabled (M48), 1=override disabled
(M49)
x −−−
592 Current line number (not block number) in the NC
program
x −−−
593 Current setpoint speed, e.g. for a spindle. Corresponds
to the value programmed for address E in the DIN block
(G0−G3).
x −−−
594 Number of the M function, by which the last
subprogram call was triggered. For use in cycles, which
are called by M functions (MK_MFKT_UPR_TABELLE).
−−−
595 Last output H function number x −−−
596 Current number of preprocessed blocks in the block
search buffer
−−−
597 Geometry counter for block progress display x −−−
598 Progress display for current traversing block:
0: Block start
1: Block end
x −−−
599 Efficiency of geometry filter G200 in % x %
610 Size of the free memory for managing NC programs Byte
611 Size of the free memory for managing symbolic
program numbers
Byte
612 Number of pending and not yet confirmed error
messages
613 Value of MK_S_VERSATZSPERRE from the machine
constants
666 ... 669 Current value of override 0 ... 3
670 Maximum value of the acceleration ramp on the path,
see G201
m/s
2
671 Maximum value of the deceleration ramp on the path,
see G201
m/s
2
672 Speed preselection for modal travel x Unit/min
673 Increment specification for step travel Unit