Interface PLC <˘> NC operating system
Extended interface for MMI functions
Data block 15
5
5.2
5.2.2
l
275
EDSTCXN EN 2.0
Data word Name Direction Type of signal
036 General override for axes HMI NC static
037 Override for spindle speeds HMI NC static
038 Override for oscillation speed HMI NC static
039 Override for PLC axes (Target
position approach)
HMI NC static
Definition of a signed evaluation factor for the currently valid traversing
speed. The specification is made in steps of 0.1 %.
Effect in the NC: The selected value is used as factor for evaluating the cur-
rently programmed maximum speed by the rough interpolator.
The override is effective in both manual as well as automatic operation. It
can be inhibited within a program via M functions.
Data word Name Direction Type of signal
040−043 Speed preselection for traverse keys HMI NC static
Definition of speed during modal traveling using the traverse keys. Specifi-
cation in [mm/min] as 64−bit floating point number.
Effect in the NC: The selected value is accepted at a fixed position in the para-
meter field. Every time the traverse key is actuated, the respective axis is mo-
ved modally at the speed entered.
Data word Name Direction Type of signal
044−047 Increment preselection HMI NC static
Definition of increment during manual traversing in inching mode. Specifi-
cation in [mm] or [inch] as 64−Bit floating point number.
Effect in the NC: The selected value is accepted at a fixed position in the para-
meter field. Every time the traverse key is actuated, the respective axis is mo-
ved about the delta specified.