Installing of the standard device
Standard devices in the power range 0.37 ... 11 kW
Thermally separated mounting (push−through technique)
4
4.1
4.1.3
4.1−3
EDSVS9332P EN 5.0−07/2013
4.1.3 Thermally separated mounting (push−through technique)
For mounting in push−through technique you have to use the controller type
EVS93xx−EP. Additionally you will require the mounting set for
push−through technique:
Type Mounting set
EVS9321−EP, EVS9322−EP EJ0036
EVS9323−EP, EVS9324−EP EJ0037
EVS9325−EP, EVS9326−EP EJ0038
a1a1
c1c1
aa
cc
gg
d1d1
d1d1
dd
b1b1
bb
LL
10
e
f
9300std063
Fig. 4.1−2 Dimensions for thermally separated mounting 0.37 ... 11 kW
9300 Dimensions [mm]
Type a a1 b b1 c c1 d d1 e
1)
f g
EVS9321−EP
EVS9322−EP
112.5 78 385.5 350 60 95.5 365.5 105.5 250 92 6.5
EVS9323−EP
EVS9324−EP
131.5 97 385.5 350 79 114.5 365.5 105.5 250 92 6.5
EVS9325−EP
EVS9326−EP
169.5 135 385.5 350 117 152.5 365.5 105.5 250 92 6.5
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
9300 Dimensions [mm]
Type Width Height
EVS9321−EP
EVS9322−EP
82 350
EVS9323−EP
EVS9324−EP
101 350
EVS9325−EP
EVS9326−EP
139 350