Configuration
Basic configurations
8
8.5
8.5−19
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0400 AIN1−OUT ) −199.99 {0.01 %} 199.99 AIN1
Display of the output signal
See system
manual
(extension)
C0402
AIN1−OFFSET 19502 FCODE−26/1 ® Selection list 1 AIN1
Offset configuration
C0403
AIN1−GAIN
19504
FCODE−27/1 ® Selection list 1 AIN1
Configuration of the gain
C0404
)
−199.99 199.99
AIN1
Display of analog input signals
1 AIN1−OFFSET
2 AIN1−GAIN
C0405 AIN1−OUT ) −199.99 199.99 AIN2
Display of the output signal
See system
manual
(extension)
C0407
AIN2−OFFSET
19503
FCODE−26/2 ® Selection list 1 AIN2
Offset configuration
C0408
AIN2−GAIN
19505
FCODE−27/2 ® Selection list 1 AIN2
Configuration of the gain
C0409
)
−199.99 {0.01 %} 199.99
AIN2
Display of analog input signals
1 AIN2−OFFSET
2 AIN2−GAIN
C0416
RESOLVER ADJ 0 0 {1} 99999999 Correction of resolver fault
For Lenze motors read out
resolver errors from nameplate
C0420
ENCODER
CONST
512 1 {1
inc./rev.
}
8192 Encoder input X8
Selection of the encoder
constant
l If an absolute value encoder
is selected in C0025, an SD7
trip is triggered when the
encoder constant is
changed.
C0421
ENC VOLTAGE 5.00 5.00 {0.1 V} 8.00 Encoder voltage
Set voltage for encoder
l CAUTION! A wrong entry can
destroy the encoder
C0425 DFIN CONST 3 0
1
2
3
4
5
6
256 inc/rev
512 inc/rev
1024 inc/rev
2048 inc/rev
4096 inc/rev
8192 inc/rev
16384 inc./rev.
DFIN
increment of the digital
frequency input
See system
manual
(extension)
C0426 DFIN−OUT ) −32767 {1 rpm} 32767 DFIN
Output signal
See system
manual
(extension)
C0427 DFIN
FUNCTION
0 0
1
2
2−phase
A pulse / B direction of rotation (right)
Pulse A or B
DFIN
Selection of the digital
frequency signal
C0429 TP5 DELAY 0 −32767 {1 inc} 32767 DFSET, DFRFG
Dead time compensation for
the touch probe function
See system
manual
(extension)
Comentarios a estos manuales