Safety instructions
Thermal motor monitoring
Self−ventilated motors
2
2.2
2.2.2
2.2−3
EDSVS9332P EN 5.0−07/2013
2.2.2 Self−ventilated motors
Due to the construction, self−ventilated standard motors are exposed to an
increased heat generation in the lower speed range compared to forced
ventilated motors.
Warnings!
For complying with the UL 508C standard, you have to set the
speed−dependent evaluation of the permissible torque via code
C0129/x.
The following codes can be set for I
2
x t monitoring:
Code Meaning Value range Lenze setting
C0066 Display of the I
2
x t load of the motor 0 ... 250 %
C0120 Threshold: Triggering of error "OC6" 0 ... 120 % 0 %
C0127 Threshold: Triggering of error "OC8" 0 ... 120 % 0 %
C0128 Thermal motor time constant 0.1 ... 50.0 min 5.0 min
C0606 Response to error "OC8" TRIP, warning, off Warning
C0129/1 S1 torque characteristic I
1
/I
rated
10 ... 200 % 100 %
C0129/2 S1 torque characteristics n
2
/n
rated
10 ... 200 % 40 %
0
0.9
0 0.1
C0129/2
0.2 0.3 0.4
0.6
0.7
0.8
1.0
1.1
1
0
0.132
2
I / I
N
n / n
N
C0129/1
3
9300STD350
Fig. 2.2−2 Working point in the range of characteristic lowering
The lowered speed / torque characteristic (Fig. 2.2−2) reduces the
permissible thermal load of self−ventilated standard motors. The
characteristic is a line the definition of which requires two points:
ƒ Point : Definition with C0129/1
This value also enables an increase of the maximally permissible load.
ƒ Point : Definition with C0129/2
With increasing speeds, the maximally permissible load remains
unchanged (I
Mot
= I
rated
).
In Fig. 2.2−2, the motor speed and the corresponding permissible motor
torque () can be read for each working point (on the
characteristic () ... ). can also be calculated using the values in
C0129/1and C0129/2 (evaluation coefficient "y", 2.2−4).
Parameter setting
Effect of code C0129/x