Lenze EVS9332xP Manual de usuario Pagina 155

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 445
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 154
Wiring of the standard device
Wiring of digital frequency input / digital frequency output
5
5.11
5.11−1
EDSVS9332P EN 5.0−07/2013
5.11 Wiring of digital frequency input / digital frequency output
Installation material required from the scope of supply:
Description Use Quantity
Protective cover Protection for unused Sub−D connections 4
Field Digital frequency output X10
Connection at drive controller Connector: Socket, 9−pole, Sub−D
Pin assignment Dependent on the selected basic configuration
Output frequency 0 ... 500 kHz
Signal Two−track with inverse 5 V signals (RS422) and zero track
Load capacity Max. 20 mA per channel
(up to 3 slave drives can be connected)
Special features The "Enable" output signal at X10/8 switches to LOW if the
drive controller is not ready for operation (e.g. disconnected
from mains). This can trip SD3 monitoring on the slave drive.
Internal voltage source
(X10/4, X10/5)
DC 5 V / max. 50 mA
Total current at X9/4, X9/5 and X10/4, X10/5: max. 200 mA
Field Digital frequency input X9
Connection at drive controller Connector: Pin, 9−pole, Sub−D
Input frequency 0 ... 500 kHz (TTL level)
Signal Two−track with inverse 5 V signals (RS422) and zero track
Signal evaluation Via code C0427
Current consumption Max. 5 mA
Special features With activated SD3 monitoring, TRIP or warning is tripped if
the "Lamp Control" input signal at X9/8 switches to LOW.
Due to this the drive controller can respond if the master drive
is not ready for operation.
Technical data