Technical data
Rated data
Operation at 480 V
3
3.3
3.3.2
3.3−2
EDSVS9332P EN 5.0−07/2013
9300 Output currents
8 kHz
1)
16 kHz
1)
Rated current Maximum
current
2)
Standstill current Rated current Maximum
current
2)
Standstill current
Type I
r8
[A] I
M8
[A] I
08
[A] I
r16
[A] I
M16
[A] I
016
[A]
EVS9321−xP 1.5 2.25 2.3 1.1 1.65 1.7
EVS9322−xP 2.5 3.75 3.8 1.8 2.7 2.7
EVS9323−xP 3.9 5.85 5.9 2.9 4.35 4.4
EVS9324−xP 7.0 10.5 10.5 5.2 7.8 7.8
EVS9325−xP 13.0 19.5 19.5 9.7 14.6 14.6
EVS9326−xP 23.5 35.3 23.5 15.3 23.0 15.3
EVS9327−xP 32.0 48.0 32.0 20.8 31.2 20.8
EVS9328−xP 47.0 70.5 47.0 30.6 45.9 30.6
EVS9329−xP 59.0 88.5 52.0 38.0 57.0 33.0
EVS9330−xP 89.0 133.5 80.0 58.0 87.0 45.0
EVS9331−xP 110 165 110 70.0 105 70.0
EVS9332−xP 145 21.5 126 90.0 135 72.0
Bold print = Lenze setting
1)
Switching frequency of the inverter
2)
The currents apply to a periodic load change cycle with max. 1 minute overcurrent duration and 2
minutes base load duration at max. 75 % I
r
3.3.2 Operation at 480 V
Basis of the data
Voltage Frequency
Supply
3/PE 480 V AC [U
r
] 320 V − 0 % ... 528 V + 0 % 45 Hz − 0 % ... 65 Hz + 0 %
DC 678 V (alternatively) [U
DC
] 460 V − 0 % ... 740 V + 0 % ˘
Output voltage
With mains choke 3 ~ 0 ... approx. 94 % U
r
˘
Without mains choke 3 ~ 0 ... U
r
˘