Wiring of the standard device
Standard devices in the power range 55 ... 75 kW
Motor connection
5
5.7
5.7.6
5.7−10
EDSVS9332P EN 5.0−07/2013
T1
T2
PE
U
VW
2
3
0
1
U, V, W,
PE
M8
15 Nm
132 lb-in
}
+
PE
M5x12
3 Nm (26.5 lb-in)
9300vec124
Fig. 5.7−6 Motor connection with KTY thermal sensor
PE stud
PE cable connection with ring cable lug
U, V, W
Motor cable connection
Check the correct polarity. Observe maximum length of the motor cable.
Max. connectable cable cross−section: 240 mm
2
with ring cable lug
Shield clamps
Place shields of motor cable with large surface on the shield sheet and
fasten with shield clamps and M5 × 12 mm screws
Cable ties
Strain relief of motor cable