Commissioning
Controlling the drive
6
6.14
6.14−1
EDSVS9332P EN 5.0−07/2013
6.14 Controlling the drive
1
2
3
4
5
6
8
9
7
Fig. 6.14−1 "Control" dialog box
Procedure
1. Click on the "Control" button in the "Basic settings" dialog box to open the "Control"
dialog box.
2.
Activate the program operation.
l Lenze setting: Set X5/E5 = HIGH.
l "Manual operation" (1) must be deselected.
3. Click "Start" (4) to enable the controller.
l If "Ok" is displayed in the "Drive diagnostics" field (5), enable can be executed.
l Controller inhibit must be deactivated (X5/28 = HIGH).
4.
Control the drive.
l The "Controller" field (6) shows the current positioning and the program status.
A Select "Program start" (9).
l The drive moves according to the loaded positioning profile.
B Deselect "Program start" (9) and select it again.
l The program restarts or is continued after an interruption ("Program stop").
C Select "Program stop" (8).
l The program execution is interrupted. The drive stops.
D Deselect "Program stop" (8).
l The program execution can be continued with "Program start".
E Select "Program reset" (7).
l The program execution is aborted. The drive stops. The piece counter and all PFOs
are reset. ( 6.11−1)
F Deselect "Program reset" (7).
l The first PS with which the program is to start is loaded.
l The program can be restarted with "Program start".
Via the "Control" dialog box you can start, stop, and reset the positioning
program and read the current program status.