Commissioning
Manual control
Setting of manual control parameters
6
6.10
6.10.1
6.10−1
EDSVS9332P EN 5.0−07/2013
6.10 Manual control
6.10.1 Setting of manual control parameters
Stop!
Uncontrolled motor movement possible.
Incorrect settings in the configuration may cause uncontrolled
movements.
Possible consequences:
ƒ The machine is damaged or destroyed.
Protective measures:
ƒ Select low values for the acceleration and speed in order to be
able to reliably check the configuration.
ƒ Select the Lenze setting. For most application cases it is
sufficient.
Fig. 6.10−1 "Manual control" menu in the parameter menu
Procedure
1. Change to the parameter menu.
2. Open the "POS functions" menu.
3. Open the "Manual control" submenu.
4. Click on code C1243 and enter a value for the manual control speed.
l Lenze setting: 5 % of v
max
5. Click on code C1252 and enter a value for the manual control acceleration.
l Lenze setting: 10 % of a
max
6. Click on code C0003 and save the settings (C0003 = 1).