Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Changing and saving parameters
7
7.2
7.2.4
7.2−5
EDSVS9332P EN 5.0−07/2013
ActionKey
sequence
Step
#
"
Quick change of digit
7.
Accept the changed parameter
Display of SHPRG or SHPRG Confirm change to accept the parameter
Display "OK"
Display The parameter has been accepted
immediately
8. Enable the controller, if
required
&
1)
The drive runs again
9.
Change to the code level
A Display of the operating level
B Display of the code with changed
parameter
10. Change further parameters Restart the "loop" with step 1. or 3.
11.
Save changed parameters
A " # $ % Select the code C0003 "PAR SAVE" in the
menu "Load/Store"
B Change to the parameter level
Display "0" and "READY"
Select the parameter set
in which the parameters
are to be saved
permanently
C "
Save as parameter set 1:
ð Set "1" "Save PS1"
Save as parameter set 2:
ð Set "2" "Save PS2"
Save as parameter set 3:
ð Set "3" "Save PS3"
Save as parameter set 4:
ð Set "4" "Save PS4"
D When "OK" is displayed, the settings are
permanently saved in the selected
parameter set.
12.
Change to the code level
A Display of the operating level
B Display of C0003 "PAR SAVE"
13. Set parameters for another
parameter set
Restart the "loop" with step 1. or 3.
1)
The function of the ' key can be programmed:
C0469 = 1: Controller inhibit
C0469 = 2: Quick stop (Lenze setting)