Application examples
8200SHB019915-10
Code settings for unit 2:
Code Name Possible settings
C
o
d
N
a
m
Lenze Choice Info
C001 Operating mode -0- -0- Setpoint selectionvia term. 8 (jumper setting
see chapter 4.2.8.2)
Control via terminals parametersetting with
8201BB
C005 Configuration -0- -0- Operation with open-loop control via
terminal 8
C014 Control mode -0- -3- Square characteristic Vf
d
2
with constant
V
min
boost
According tothe information given in both tables (code setting for unit 1 and 2):
1. All other parameters are based on the factory setting.
2. Set the rated motor data under C088 (rated motor current) and C091 (motor cos Ö)depending on the motor
connected.