Configuration
8200SHB01997-42
7.5.11.2 Setpoint input using the keypad
Function If you selectthe operatingmode C001 = -1-, the setpoint canbe selectedbymeansof the keypad
of the operating module.
Adjustment 1.Press keyor .
2.The display changes and indicates the current setpoint together with SET.
3.Set the setpoint using or .
- If the controller is enabled, the changed setpoint has a direct effect on the drive.
- The setpoint is saved when the controller is inhibited. After the controller has been enabled, the
drive accelerates ordeceleratestothe last setpoint.
Important Setpointsselected bymeansof the keypadare saved when separatingthe controller fromthe mains
or interrupting the operation. The drive can start again after controller enable!
Observe the start conditions under C142:
Series “Standard”: See chapter 7.8, ”Code table”.
Series “HVAC”: See chapter 7.9, ”Code table”.