Lenze 8200 Frequency inverters Manual de usuario Pagina 184

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 311
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 183
Configuration
8200SHB0199
7-47
7.5.11.6 Setpoint sum
Only HVAC” controllers
Code Name Possible settings IMPORTANT
C
o
d
N
a
m
Lenze Choice Info
I
M
P
O
R
T
A
N
T
C049* Additional setpoint -480.00 {0.02 Hz} 480.00 Display only
Function In controlled operation(C005 = -1-, -2-) the setpoint sum can be generated with
the signal of the analog input (terminal 8) or
the digital frequency at terminal E1 or
the function Motor potentiometer or
the process setpoint C046 (LECOM).
The additional setpoint is indicated under C049.
Special features The displayvalue of the parameter canbe relatedtoanapplication datum(C500, C501).
(see chapter7.6.3)
Show/Hide Bookmarks
Vista de pagina 183
1 2 ... 179 180 181 182 183 184 185 186 187 188 189 ... 310 311

Comentarios a estos manuales

Sin comentarios