Configuration
8200SHB01997-94
Code IMPORTANTPossible settingsNameCode IMPORTANT
InfoChoiceLenze
Name
C182* Integration time
ramp function
generator S-shape
0.00 0.00 {0.01 s} 50.00 Page 7-32 C182 = 0.00
- Linear ramp
function generator
C182 > 0.00
- Ramp function
generator S shape
with
T
i
time = C182
C196*¤ Input condition
autom. DC injection
brake
-0- -0- DC brake active at C050 < C019
-1- DC brake active at C050 < C019
and Setpoint < C019
Page 7-56
C200 Software EKZ
C238¤ Frequency
precontrol
-1- -0- No precontrol
-1- With setpoint precontrol
Page 7-34,
7-39
C239¤ Frequency setting
range
-0- -0- Bipolar
-1- Unipolar
Page 7-39
C304 Password1
C305 Password2
C307 Contents of the
address
Should only be
C308 Address
C377*¤ Gain voltage
detection
822X/824X
C395 LWO R D p r o c es s
input data
C396 LWO R D p r o c es s
output data
C425¤* Adjustment of digital
frequency
-2- Dig.- Reso- Scann- Max.-
freq. lution ing freq.
-0- 100 Hz 1/200 1 s 300 Hz
-1- 1 kHz 1/200 100 ms 3 kHz
-2- 10 kHz 1/200 10 ms 10 kHz
-3- 10 kHz 1/1000 50 ms 10 kHz
-4- 10 kHz 1/10000 500 ms 10 kHz
Page 7-60 When using the
analog input module
9279 for the
frequency input E1:
Set C425 to2, 3
or 4
C426* Gain adjustment
frequency input E1
100 -200.0 {0.1 %} 200.0 Page 7-60
C427 Offset adjustment
frequency input E1
0.0 -12.5 {0.1 %} 12.5 Page 7-60
C500* Display factor
2000 1 {1} 25000 Page 7-63
numerator
C501* Display factor for
10 1 {1} 25000 Page 7-63
denominator
C597*¤
Activation of motor
phase failure
detection
Page 7-73
822X/824X -0- -0- Inactive
-1- TRIP
-2- Warning
Comentarios a estos manuales