Lenze EVS9332xP Manual de usuario Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 334
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
Function library
Positioning control
3.4.6 Control structure
3−43
l
EDSVS9332P−EXT DE 2.0
Important signals for adjusting the control loops
The following signals are especially suitable for evaluating the positioning behaviour and control
features:
l POS−NOUT: Speed setpoint, 100 % º n
max
(C0011)
l MCTRL−NACT: Actual speed value, 100 % º n
max
(C0011)
l MCTRL−MSET2: Actual torque, 100 % º M
max
(C0057)
l POS−POUT−NORM: Actual following error, 100 % º Following error tolerance (C1218/1)
Tip!
The code table can be found in the system manual, document number EDSVS9332P.
Vista de pagina 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 333 334

Comentarios a estos manuales

Sin comentarios