Lenze EVS9332xP Manual de usuario Pagina 293

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 334
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 292
Function library
Function blocks
3.5.62 Multi−axis synchronisation (SYNC1)
3−265
l
EDSVS9332P−EXT DE 2.0
3.5.62.3 Phase displacement
Phase displacement for synchronisation via system bus (SYNC TIME)
Code Value Function
C1122 0 ...10.000 ms · C1120 = 1
Phase displacement between the sync telegram and the start of the internal control program.
The parameters are set automatically depending on the parameter setting of the system bus (CAN).
· C1120 = 2
C1122 has no effect.
Phase displacement for synchronisation via terminal (PHASESHIFT)
Code Value Function
C1123/1 −1.000 ms
to
+1.000 ms
· C1120 = 1
C1123/1 has no effect.
· C1120 = 2
Phase displacement between the sync signal and the start of the internal control program (e. g. for
compensating the effects of signal propagation delays/dead times for the sync signal of the single
slave drives).
3.5.62.4 Time slot for synchronisation via terminal
Code Value Function
C1123/2 0 ... 1.000 ms · C1120 = 1
C1123/2 has no effect.
· C1120 = 2
Definition of a "time slot" for the LOW−HIGH edges of the sync signal for the slave (defined via
C1121/1).
If the sync signal sent by the master is within the "time slot", the SYNC1−STAT is switched to HIGH.
S Y N C - C y c l e ( C 1 1 2 1 / 1 )
S Y N C - W i n d o w ( C 1 1 2 3 / 2 )
S Y N C - S i g n a
l
Fig. 3−211 Time slot" for the LOW−HIGH edges of the sync signal
Tip!
A jitter of up to ±200 μs on the LOW−HIGH edges of the sync signal is permissible. The size of the
jitter affects the parameter setting of the "time slot".