Function library
Function blocks
3.5.68 Variable table Waiting time (VTTIME)
3−280
l
EDSVS9332P−EXT DE 2.0
Function
A total of 34 table positions are available.
l Enter fixed time value under C1305.
30 table positions (VTTIME−No1 ... VTTIME−No30) are available.
Subcodes (C1305/1 ... C1305/30) define the table position number.
l Enter variable time values under VTTIME−INx.
4 table positions (VTTIME−No31 ... VTTIME−No34) are available.
Signal input via function blocks.
The time values must be transmitted to the table positions before the program set starts
and has access to it.
l C1387 displays the time values on the table positions.
Select table position (C1387/1 ... C1387/34) with subcode.
Note!
Entries into the processing table are necessary only if the FB inputs and outputs are used.