Lenze EVS9332xP Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 334
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
Function library
Working with function blocks
3.1.3 Connecting function blocks
3−10
l
EDSVS9332P−EXT DE 2.0
Create connections
1. Determine the signal source for ARIT2−IN1:
Change to the code level using the arrow keys
Select C0601/1 using or .
Change to the parameter level using PRG.
Select output AIN2−OUT (selection number 55) using or .
Confirm using SH + PRG
Change to the code level again using PRG.
2. Determine signal source for ARIT2−IN2:
Select C0601/2 using .
Change to the parameter level using PRG.
Select output AIN2−OUT (selection number 55) using or .
Confirm using SH + PRG
Change to the code level again using PRG.
3. Parameterise ARIT2:
Select C0600 using .
Change to the parameter level using PRG.
Select multiplication (selection number 3).
Confirm using SH + PRG
Change to the code level again using PRG.
4. Determine signal source for AOUT1:
Select C0431 using .
Change to the parameter level using PRG.
Select output ARIT2−OUT (selection number 5505).
Confirm using SH + PRG
Change to the code level again using PRG.
5. Enter function block ARIT2 in the processing table:
Select C0465 and subcode 8 using .
Change to the parameter level using PRG.
Enter function block ARIT2 (selection number 5505).
Confirm using SH + PRG
Change to the code level again using PRG.
The sequence of the FB processing is thus determined.
Vista de pagina 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 333 334

Comentarios a estos manuales

Sin comentarios