Function library
Positioning control
3.4.11 Program operation
3−72
l
EDSVS9332P−EXT DE 2.0
Resetting the program (PRG−RESET)
l POS−PRG−RESET = HIGH or C1280.B2 = 0 (Program reset" in the GDC dialog "Control").
l When a program is reset,
the drive will be stopped with a−max (C1250) (no influence of POS−A−OVERRID)
the program will be interrupted
Program end" will be set
the piece counter will be set to zero
the program function outputs (PFO) will be reset
the touch probe inputs used by the program will be disabled"
and if necessary, stand−by operation will be cancelled.
Tip!
The signal for resetting the program is also accepted and saved in the inhibited state. The program
reset will only be executed in the released state (see notes under "starting the program").
Cancelling the current PS (PS−CANCEL)
l LOW−HIGH signal at POS−PS−CANCEL or C1280.B3 = 0 / 1 signal.
The drive will be decelerated to standstill with the separately adjustable delay a−cancel"
(C1253).
The program will be continued in the PS selected (C1333; JMP−TP−PS).