Function library
Function blocks
3.5.30 Digital frequency processing (DFSET)
3−181
l
EDSVS9332P−EXT DE 2.0
Synchronisation mode
For the synchronisation, different modes are available which can be set under C0534.
C0534 Synchronisation mode Note
0 Synchronisation not active
1 Permanent synchronisation with direct correction of the angular
difference (counter−clockwise or clockwise rotation).
2 Permanent synchronisation with direct correction of the angular
difference (counter−clockwise or clockwise rotation).
A LOW−HIGH edge at DFSET−0−pulse activates a continuous
synchronisation.
10 One−time synchronisation with direct correction of the angular
difference (counter−clockwise or clockwise rotation).
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.
11 One−time synchronisation with correction of the angular
difference in clockwise rotation.
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.
12 One−time synchronisation with correction of the angular
difference in counter−clockwise rotation.
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.
13 One−time synchronisation with correction of the angular
difference. The difference is determined between the setpoint
pulse and actual pulse and is corrected to the corresponding
direction of rotation according to the sign.
A LOW−HIGH edge at DFSET−0−pulse activates a one−time
synchronisation.